電路圖










(Control Shutoff, Power Standby, Sleep Mode, Battery Capacity
Detection, Fuel Position Recognition; Communication: Operating
Indicator, Fault Indicator, Oil Indicator, Idle Speed, Reset, Frequency
Switching, One-Touch Start/Stop, Fuel Level Display)
GND
30A
20A
W
N
Y
L
G
E
GND
GND
GND
BAT
+12V
VDD
+12V
GND
CO
Red
Light
CO
Green
Light
CO-
TXRX Wakeup
Trigger
Fuel Block
Solenoid
Valve
Spark
Plug
High
Voltage
Pack
Fuel Pressure
Sensor
Fuel Level
Sensor
Accelerator
Step Motor
Accelerator
Step Motor
Temperature
Sensor

GND
High-
Voltage
Winding 4
Power
Supply
Winding 3
Power
Supply
Winding 2
Power
Supply
Winding 1
Ignition
Winding
Three-Phase
Main Winding

LPG fuel position:
Pins 5 and 6
conducting (solenoid
valve powered on for
oil blockage).
Remaining position:
5 and 6 pins
disconnected
OFF: Pins 1
and 2
conducting,
forced shutoff.
Remaining
position: Pins
1 and 2
disconnected
OFF: Pins 3
and 4
conducting.
Remaining
position: Pins
3 and 4
disconnected
ignition
cut-off
line
OFF: Pins 7 and
8 disconnected,
power off main
package.
Remaining
position: 7 and
8 pins
conducting
OFF: Pins 9 and
10 disconnected,
power off PD
board and
controller.
Remaining
position: Pins 9
and 10 conducting

󽗿