3.0 SYSTEM INSTALLATION
3.1
Preplanning
There is no substitute for planning the installation prior to beginning the work. Several minutes in planning
may save an hour or more during the installation. The following is a list of factors to consider before the
installation of the system begins.
Under normal installation procedure the Pump Cabinet MUST BE located within 50-feet (15 meters) of all 3
laundry machines. Outlet tubing should not exceed 50-feet in length under normal operation. This is
important to know when positioning the Pump Cabinet. A shorter distance is preferable to help reduce post-
flush times. Long dispense distances require extended flush times.
The dispenser system comes with (5) 4.2m (14-feet) long and (2) 7.6m (25-feet) long RS-485
communication cables. Optional 15m (50-feet) communication cables are available. This is important to
know when positioning the modules.
The Pump Cabinet MUST BE mounted at or below the operator’s eye-level. Ease of capsule replacement is
important.
Pump Cabinet’s wall mounting bracket MUST BE securely anchored to the wall. On sheetrocked walls, align
the center mounting hole to a wall stud or separately order toggle bolts (see below).
Allow sufficient space around the perimeter of the cabinet for capsule replacement and servicing. It is
recommended to allow 20 cm (8-inches) above Pump Cabinet.
3.2 Materials Ordered Separately
• Backflow Prevention Code 10004965 ; 10002009 and 10000440.
• 1/2-inch O.D., 3/8-inch I.D., Polyflo (PolyEthylene, PE) tubing used for product delivery from the
Pump Cabinet to the laundry machine(s). This rigid tubing withstands higher temperatures than soft
EVA.
• The 5/8-inch I.D. Mayon tubing used for the overflow is not included in the installation kit.
• 1/2-inch conduit or Seal-Tite with connectors and fittings (hardwired power source and supply
signals).
• Electrical plug for power cord must be sourced and installed separately.
• A main switch (EBS Nr. 10010678) or non symmetric plug is mandatory.
• Proper wall anchors or toggle bolts should be used on sheetrock walls.
• Water Tempering Valve Kit if the account hot water temperature is greater than 60°C.
• Optional 15m (50-feet) RS-485 communication cable are available.
• Optional L-brackets for mounting Condor Controller or FS modules.