EasyManua.ls Logo

Ecolab Aquanomic - Programming

Ecolab Aquanomic
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 17
The RS-485 cables are connected in a daisy-chain fashion. The first and last module in the sequence will have an open communication port.
A RS-485 plug or “dongle” must be plugged into the first and last open connector. There are (2) plugs in the install kit.
1. Mount all modules on the wall or machine.
2. Route cables from one module to the next module in a daisy chain sequence.
3. Now with all modules cabled together, go to the first and last module in the daisy chain sequence and
install a RS-485 plug or dongle in the (2) remaining ports. (The Condor may already have a dongle pre-
installed.)
4. Secure cables with zip ties for a clean installation.
All electrical connectors are keyed to fit one way only. Do not force the connections.
If you need to unplug a cable or plug- be careful. They have a locking mechanism tab that must be squeeze to release the tab. This squeeze
takes a lot of effect- for a very strong hold during normal operation.
Seven (7) RS-485 communication cables are included with the dispenser. All will be needed if the account has (3) laundry washers and all FS
modules are used. If longer or more cables are needed, they are ordered separately.
Do not secure or wrap the communication cables around, or near, any high voltage cables or components (48V or greater).
If communication is lost at any point in the sequence, all modules following this connection will also lose
communication. For example, if communication is lost or a communication cable is accidentally severed
(unplugged or cut) at Washer #1, communication will be lost to Washer #2 and Washer #3 and these
machines will not be serviced by the dispenser.
3.4.3. I/O (Input/Output) Board Cable (inside Pump Cabinet)
1. After Pump Cabinet is securely hanging on the wall, remove metal front cover, using keylock.
2. Remove plastic cover from plastic enclosure with (4) screws, the I/O board is inside.
3. Remove white plastic split strain reliefs in bottom of enclosure. The RS-485 cable will run through these.
4. Connect RS-485 cable to board and run cable over to closest module. Make sure to use the white
plastic split strain reliefs to capture cables.
5. Repeat step 4 or place Plug into port, if this module is the first or last in the chain of cables.
3.4.4. Condor Controller Cable
1. Remove Condor Controller from mounting bracket and remove back cover by loosening (2) retaining
screws.
2. Inside the Condor Controller only, you will find a termination plug already installed. If you wish this
module to be the first or last in the daisy chain, keep installed. Otherwise, remove the plug and place
into a different module that needs a terminating cable plug.
3. Connect either (1) or (2) communication cables of suitable length to make up the daisy chain of cables.
Replace back cover.
4. Attach Condor Controller back to mounting bracket.
Addresses must be consecutive. For example, if 3 washers are used, addresses must be set up as 1, 2, 3.