Page 24
3.6.3. Installation Procedure
1. Remove the
label from the left side of the Pump Cabinet’s left hand side. The label needs to be removed
in order to run the electrical and hydraulic service between the 2 cabinets.
2. If the
Pump Cabinet has already been installed, remove the cabinet from the wall to access the Wall
Bracket. Following instructions below:
a. Unplug the electrical cord for the Pump Cabinet.
b.
Turn off the water supply. Might need to disconnect the incoming water plumbing.
c.
Disconnect the product delivery tubing, if needed.
d.
Remove the overflow hose, if needed.
e. Remove the solid products.
f. Remove Cabinet from the wall to access the Wall Bracket.
Mounting 4
th
Solid Product Cabinet
3.
Align the brackets together. Drill holes, insert wall anchors, and screw bracket tightly to the wall.
Wiring
1. Unwind the
ORANGE, WHITE/ORANGE and RED, WHITE/RED wire pairs in the Pump Cabinet and
feed through the top hole in the left side of the Pump Cabinet.
2.
Crimp a 1/4-inch female quick disconnect to each of the four wires. Might want to cut to length.
3.
Connect the orange wire to the male quick disconnect of the capsule safety switch (white wires).
4. Connect the white / orange wire to the open tab of the 4th product
solenoid
valve.
5. Connect the red and the white / red wires to the open tabs on the flush
solenoid
valve.