2.0 REQUIREMENTS/SPECIFICATIONS
2.1. Utility Requirements
2.1.1 Electrical Supply Requirements
A constant 230 VAC / 50 - 60 Hz. power source is required.
The Pump Cabinet is shipped with a 2.7m (9-foot) power cord.
A main switch (EBS Nr. 10010678) or non symmetric plug is mandatory.
The ON / OFF circuit breaker switch is rated at 3.0 amps.
Total amperage draw during normal operation is less than 1.8 amps.
2.1.2.Water Supply Requirements
Water temperature should be between 49°C 60°C (120°F 140°F).
Water supply pressure: 1.5 1.8 bar (22 - 26 psi) (during dispense mode).
Water flow rate is 3.0 4.5 liters/min (0.8 - 1.2 GPM).
Risk of Injury
- Contact with contents can cause skin burns and serious eye injury.
- Wear eye and skin protective equipment.
Refer to Product Safety Data Sheets for further information.
Complex Requests from different washers will be dosed in a FIFO (First In, First Out) basis and do not have the ability to be split up (unlike the
case of one complex request with multiple simple requests) so use caution when setting up Product Delays to prevent the system from
sitting idle waiting for different Product Delays to expire.
To avoid operator exposure to chemical products, the queue system will automatically cancel the final step of a wash formula if it is in queue
(waiting) for longer than 3 minutes. If the final washer step includes a chemical dose, it is important that the washer step programmed length
is greater than 3 minutes.