EasyManua.ls Logo

Ecolab Aquanomic - Installation

Ecolab Aquanomic
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 28
3.8. Optional 4
th
Liquid Product Pumps
The Aquanomic EU dispenser can also dispense 1 liquid product to all 3 washers using the Turbo Smart
Pump (TSP).
The discharge tubing that delivers the liquid product to the washer(s) will run separately, for now.
When using the liquid pumps, you can also install Out Of Product float switches inside the liquid product’s
pail(s).
3.8.1. Installation
1. Mount the TSP backplate to the wall.
2. Connect 24VDC wiring from the I/O board (inside the Pump Cabinet) terminals in lower left corner. P1
represents Pump #1 for Washer #1. Attach the wire connections in the TSP backplate module.
3. Attach Pump Module to backplate.
4. Run pickup tubing from liquid pail to inlet (bottom) of Pump. Attach float switch to pickup probe for OOP
alarms. Run wires to I/O board in lower middle terminals. Connect wires to S and terminals and wires
float switches in series or parallel, depending on number of liquid product pails used.
5. Connect discharge tubing from outlet (top) of Pump and run tubing over to chemical hopper injection on
designated laundry washing machine. Use 3/8” ID braided EVA tubing.
6. Program Condor Controller with product selection and feed times.
I/O circuit board wiring for liquid product pumps and floats: