EasyManua.ls Logo

Ecom j2kn pro - Page 23

Ecom j2kn pro
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ecom-J2KN
pro
Page 23
The result of the oil trace check is to be documented as follows:
-Set the cursor on the line "Oil trace".
-Input the result with <OK>
("NO", "YES" or "- - - ")
-Press <ESC> to quit the menu once all necessitated inputs have
been entered. The measurement is now completed.
Get the probe cooled down before putting
it back in its fixation!
Soo
t..Oil trace
Mean value
:
1.0
Boiler temp.: 66°C
1st Soot meas.: 1.0
2nd Soot meas.: 0.5
3rd Soot meas.: 1.5
Oil trace : NO

Other manuals for Ecom j2kn pro