Shows current weather and forecast; tap for more details.
Provides access to contractor information and support.
Allows entering preset Away settings or returning to previous settings.
Displays the current indoor temperature.
Navigates to settings, schedules, and more.
Indicates important reminders, minor or critical alarms.
Shows WiFi signal strength and access setup.
Displays current relative humidity and allows configuration.
Navigates to mode selection (Auto, Heat, Cool, etc.).
Icons for Schedule, Service, Settings, Status, Water Heater.
Icons for Auto, Cooling, Heating, Emergency Heat, Fan Only, Power Off.
Icons representing Home and Away modes.
Icon indicating alerts or alarms.
Icons for Connected Strong, Medium, Low, and Not Connected signals.
Icons representing various weather conditions like Clear, Cloudy, Rain, Snow.
Explains how the motion sensor wakes the thermostat.
How to turn off the standby screen backlight via settings.
System activates heating/cooling to maintain set point range.
Turns on heating when temperature drops below set point.
Turns on cooling when temperature rises above set point.
Emergency heat option for heat pump systems.
Turns off heating/cooling, allows fan-only operation.
Displays current local weather details.
Shows the hourly weather forecast.
Displays the extended weather forecast.
Access system-level settings and preferences.
Adjust thermostat and basic equipment settings.
Minimum difference between heat/cool set points in Auto.
Adjusts displayed room temperature reading.
Adjusts displayed indoor relative humidity reading.
Choose internal, remote, or average sensor for temperature.
Enable/disable motion sensor for screen activation.
Ensures set point is reached by scheduled time.
Controls standby screen backlight.
Enable or disable daylight savings time.
Reduce humidity in cooling mode.
Target relative humidity for dehumidification.
Degrees the system can over-cool for dehumidification.
Duration fan is off after cooling cycle for drainage.
Control humidifier attached to furnace/air handler.
Target relative humidity for humidification to activate.
Select modes for humidification (Heat, Fan, Cool).
Prevents condensation by adjusting humidification.
Forces fan on for humidification when heating/cooling is off.
Select fan speed for continuous air circulation.
Steps to edit schedule times and set points for a day.
How to copy one day's schedule to other days.
How to return to scheduled operation after manual override.
Displays detailed furnace operation and historical cycles.
Displays detailed AC/HP operation and historical cycles.
Displays detailed air handler operation and historical cycles.
Shows currently active alerts or alarms.
Lists past alerts/alarms with timestamps.
Set time-based maintenance reminders.
Enter and access preferred contractor contact information.
Displays model, serial, and software version of connected equipment.
View the current operation state of the water heater.
View and modify the water heater set point.
Elect water heater to follow vacation event settings.
Receive notifications for water heater alarms.
Guidelines for where to mount the thermostat.
Locations to avoid for thermostat placement.
Explains the daisy chain wiring method for network units.
Details the function of each terminal on the connector.
Guidance on using shielded wire for interference reduction.
Choose sensor input in settings.
Shows resistance values for temperature sensor at different temps.
Configure furnace-specific settings like blower delay and airflow.
Sets normally open/closed for AUX inputs.
Defines actions based on AUX input status (Off, Float Switch, etc.).
Selects filter type for air filter service reminders.
Sets the installation elevation for system calibration.
Choose the type, stages, and tonnage of the outdoor unit.
Reduces maximum compressor speed to lower noise or airflow.
Adjusts airflow in cooling and heat pump heating modes.
Enables load shedding device connection.
Selects furnace or heat pump as the primary heat source.
Sets temperature above which furnace/electric heat is locked out.
Sets temperature below which heat pump is locked out.
Automatically populated based on equipment model data.
Sets duration auxiliary heat is held off.
Sets time of day for air filter status check.
Controls system cycling to prevent over/under shooting set points.
Select the appropriate size for installed electric strip heaters.
Choose from four options for electric heat airflow settings.
How to clean the thermostat screen safely.
Procedure to restart the thermostat by cycling power.
Statement regarding compliance with FCC rules for digital devices.
Information on FCC limits for radio frequency exposure.
Statement regarding compliance with Industry Canada standards.