Page 14 Solution-8 Operators Manual
Electronics Design & Manufacturing
M
A800O3C.DOC
Alarm Memory Recall
+
3
+
This feature allows you to playback the last ten events that have occurred to the system.
The RECALL mode reports all alarms and arming or disarming of the system in the
STAY or AWAY modes. This function helps with trouble shooting of the system. The
alarm memory events are displayed via the console indicators.
To enter the ALARM MEMORY RECALL mode key in your MASTER CODE
followed by the number '3' then the AWAY button. Three beeps will be heard to
indicate successful entry to the ALARM RECALL MODE.
The events will be played back via the zone indicators on the console in reverse
chronological order.
Example:
If the events were as follows:
1
System armed
2
Alarm zone 3
3
Alarm zone 4
4
System disarmed
Then the alarm memory playback will report as follows:
1
All indicators off except mains
indicator
System disarmed
2
Zone 4 indicator illuminates Zone 4 alarm
3
Zone 3 indicator illuminates Zone 3 alarm
4
Away indicator illuminates Zone armed in away mode
Each event is indicated by a beep and an illuminated indicator. Resetting a 24 hour
alarm in the disarmed state is indicated by a beep only.
After the tenth event three beeps will be heard to indicate the end of playback. The
replay can be terminated at any time by pressing AWAY.