Walk Test Mode
+
4
+
Using Walk Test Mode you can test detection devices to ensure that they are functioning
correctly, eg: to check a reed switch on a door.
To turn Walk Test on, isolate any zones that are not required for walk testing (see
manually isolating one or more burglary zones).
Now key in the MASTER CODE followed by the number '4' then AWAY button. Three
beeps will be heard indicating successful entry into the Walk Test mode. The console
will beep once every second while the system is in the walk test mode.
Every time a zone is sealed or unsealed the external siren (SPK1 & SPK2) will sound a
single beep and the system console will give a long beep indicating that the zone is
functioning correctly.
To turn Walk Test off press the AWAY button, two beeps will be heard and the system
will return to normal.
Console Duress Alarm
+
9
+
or
+
9
+
This function allows the system to be disarmed and at the same time initiate a duress
signal via the dialler to the monitoring station.
A Duress alarm will only work when you are disarming the control panel and no visual
display will be given to indicate that a duress alarm has been successfully activated.
To initiate this silent alarm key in any of the system codes followed by the number '9'
then the AWAY button.
The system will appear to disarm normally but will in fact activate the dialler (where
programmed) causing it to call the monitoring station.