Technical Data
S900-01-880 Issue C
2Technical Data
2.1 Operating and storage conditions
2.2 Pump technical data
Performance data, electrical data and mechanical data for the booster pumps are provided in Tables 3 to 8.
Table 2 - Operating and storage conditions
Ambient operating temperature range 12 to 40 ºC (54 to104 ºF)
Ambient storage temperature range -30 to 70 ºC (-22 to 158 ºF)
Normal surface temperature of the pump body at ultimate
vacuum (operation), ambient temperature of 20 ºC (68 ºF)
50 to 70 ºC (122 to 158 ºF)
Maximum ambient operating humidity 90% RH
Table 3 - Technical data: 607-MH/MV05, 607-MH/MV20, 615-MH/MV10 and 615-MH/MV15 direct drive MSeal
booster pumps (with NEMA motors)
900-607-MH05
900-607-MV05
900-607-MH20
900-607-MV20
900-615-MH10
900-615-MV10
900-615-MH15
900-615-MV15
Pumping speed 1040 m
3
h
-1
612 cfm
1040 m
3
h
-1
612 cfm
2210 m
3
h
-1
1300 cfm
4420 m
3
h
-1
2600 cfm
Nominal power 3.75 kW
5 hp
15 kW
20 hp
7.5 kW
10 hp
11 kW
15 hp
Voltage 230/460 V ac 208-230/460 V ac 208-230/460 V ac 208-230/460 V ac
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Phases 3333
Enclosure TEFC IP55 TEFC IP55 TEFC IP55 TEFC IP55
Full load current 13 A/6.6 A 53 A/48 A/24 A 27.2 A/24.6 A/
12.3 A
39.8 A/36 A/18 A
Motor speed 1725 r min
-1
1725 rpm
1760 r min
-1
1760 rpm
1750 r min
-1
1750 rpm
3500 r min
-1
3500 rpm
Recommended fuse/circuit
breaker
20 A/10 A 70 A/35 A 35 A/17.5 A 50 A/25 A
Dimensions Figures 4 and 5 Figures 4 and 5 Figures 4 and 5 Figures 4 and 5
Total mass (pump and
motor)
274 kg
603 lb
406 kg
897 lb
385 kg
847 lb
392 kg
865 lb
Motor mass 34 kg
75 lb
167 kg
367 lb
84 kg
185 lb
91 kg
200 lb

Table of Contents