S900-01-880 Issue C
Page 12 © Edwards Limited 2008. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical Data
Table 6 - Technical data: 61BMHR/MVR601 and 622MHR/MVR601 direct drive MSeal booster pumps (with IEC
motors)
90061BMHR601 *
90061BMVR601 *
900622MHR601 *
900622MVR601 *
50 Hz operation 60 Hz operation 50 Hz operation 60 Hz operation
Pumping speed 3684 m
3
h
-1
2167 cfm
4420 m
3
h
-1
2600 cfm
5440 m
3
h
-1
3200 cfm
6258 m
3
h
-1
3840 cfm
Nominal power 18.5 kW
25 hp
18.5 kW
25 hp
18.5 kW
25 hp
18.5 kW
25 hp
Voltage 200/400 V ac 230/460 V ac 200/400 V ac 230/460 V ac
Frequency 50 Hz 60 Hz 50 Hz 60 Hz
Phases 3333
Enclosure IP55 IP55 IP55 IP55
Full load current 57.2 A/28.6 A 67 A/33.5 A 57.2 A/28.6 A 67 A/33.5 A
Motor speed 2950 r min
-1
2950 rpm
3550 r min
-1
3550 rpm
2950 r min
-1
2950 rpm
3555 r min
-1
3555 rpm
Recommended fuse/circuit breaker 70 A/35 A 90 A/50 A 70 A/35 A 90 A/50 A
Dimensions Figures 6 and 7 Figures 6 and 7 Figures 6 and 7 Figures 6 and 7
Total mass (pump and motor) 538 kg
1185 lb
538 kg
1185 lb
624 kg
1375 lb
624 kg
1375 lb
Motor mass 116 kg
260 lb
74 kg
163 lb
145 kg
319 lb
145 kg
319 lb
* These are CE-compliant dual-frequency booster pumps