Technical data
2.8 Temperature control system
Note: The CDX temperature sensor senses the temperature of the oil in the end cover, and is a safety-critical
device for ATEX systems. If applicable, refer to the ATEX system instruction manual for details.
Tab le 8 - Tem p erat u re C o nt ro l S ys te m Da t a
2.9 Connections
Tab le 9 - Co nn e c t io ns
WARNING
If the CDX pump is part of an ATEX system, there may be an operating case temperature limit. Refer
to the ATEX system instruction manual for details.
Water cooling system
Typ e
Coolant capacity
TCV (Thermostatic Control Valve)
Sensor operating temperature range
Maximum sensor temperature
CDX temperature sensor (see Note above)
Typ e
Sensing range
IDX warning thermal snap-switch
Opening temperature
Closing temperature
IDX shut-down thermal snap-switch
Opening temperature
Closing temperature
Indirect water-to-coolant heat exchanger
50 l (13.2 US gal)
10 to 80 °C (77 to 176 °F)
130 °C (266 °F)
Platinum resistance thermometer (PRT)
0 to 200 °C (32 to 392 °F)
88 °C (190 °F)
78 °C (172 °F)
95 °C (203 °F)
85 °C (185 °F)
Process connections
Pump inlet
Pump outlet
Recommended inlet and outlet seals
Cooling water connections
Supply inlet
Return outlet
Shaft-seals purge gas inlet
150 DIN
*
or 6 inch ANSI
80 DIN
*
or 3 inch ANSI
PTFE envelope gaskets: Klinger milled type with a
1.5 mm (0.06 inch) full-face insert
½ inch BSP male
*
or ½ inch NPT male
½ inch BSP male
*
or ½ inch NPT male
¼ inch compression
*
50 Hz pumps
60 Hz pumps