The diameter of the outer sheath of the electrical supply cable must be within the range
7 mm to 10.5 mm. The cable must conform in size and colour coding with the local and
naonal electrical installaon regulaons. The temperature rang of the cable must be
70 °C or greater.
Table 10
Motor connecon details
Pump item number
Voltage
(V)
Frequency
(Hz)
Connecon details:
refer to Figure
A36315903, A34315903
(all) 50/60 Figure: Three-phase motors: 200-220 V
50 Hz and 200-230 V 60 Hz on page 28
A34315981, A36315981
115 60 Figure: Single-phase motors: 100 V 50
Hz, 100-105 V 60 Hz and 115 V 60 Hz on
page 24
230 60 Figure: Single-phase motors: 200 V 50
Hz, 200-210 V 60 Hz and 230 V 60 Hz on
page 25
A34315904, A36315904
100
100 - 105
50
60
Figure: Single-phase motors: 100 V 50
Hz, 100-105 V 60 Hz and 115 V 60 Hz on
page 24
200
200 - 210
50
60
Figure: Single-phase motors: 200 V 50
Hz, 200-210 V 60 Hz and 230 V 60 Hz on
page 25
A34316903
(all) 50/60 Figure: Single-phase motors with
Amphenol connector: 220-240 V 50 Hz
and 230-240 V 60 Hz on page 25
A34317984, A36317984,
A34317984, A36317984
(all) 50/60 Figure: Motor voltage selecon: single-
phase motors, 110/200-240 V 50 Hz and
115-120/200-240 V 60 Hz on page 26
4.6.1 Standard single-phase motors
1. Remove the cover from the motor terminal box (Figure: General view of the pump
on page 11).
2.
Remove the cable-gland from the inside of the terminal-box and t the cable-gland
to the cable lead-through hole in the side of the terminal-box. Using a tool this
should be ghtened to a torque of 3.75 Nm.
3.
Pass the electrical supply cable through the gland.
4.
Remove the receptacle connectors from the ng pack.
5.
Fit a ring connector to the earth (ground) wire.
6.
Select the correct size of receptacle connectors for the cable wires:
Use the red connectors for wire sizes 0.75 mm
2
to 1.5 mm
2
.
Use the blue connectors for wire sizes 1. 5 mm
2
to 2.5 mm
2
.
7.
Aach the appropriate connector to the live and neutral wires.
8.
Connect the electrical supply cable to the appropriate terminals as shown in:
Figure: Three-phase motors: 200-220 V 50 Hz and 200-230 V 60 Hz on page 28
Page 22
A34310880_T - Installaon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M18 and is the answer not in the manual?

Edwards E2M18 Specifications

General IconGeneral
BrandEdwards
ModelE2M18
CategoryWater Pump
LanguageEnglish

Related product manuals