7.4 The pump surface temperature is above 100 °C
The ambient temperature is too high.
The cooling-air supply is insucient or is too hot.
The cooling-air supply is blocked.
The electrical supply voltage is too high.
The exhaust lter or exhaust line is blocked.
The oil level is too low.
The pump is lled with the wrong type of oil.
The oil is contaminated.
The process gas is too hot or the throughput is too high.
7.5 The vacuum is not maintained aer the pump is switched o
The gas-ballast control is open.
O-ring(s) are damaged or missing.
The sha seals have deteriorated.
7.6 The pumping speed is poor
The connecng pipelines are too small in diameter.
The connecng pipelines are too long.
The inlet-lter is blocked.
7.7 There is an external oil leak
The oil pump sha seal is worn or damaged.
The oil box gasket has deteriorated.
There is an oil leak from gas-ballast control.
There is an oil-leak from the drain-plug.