Technical Data
Note: Only slm gas flow values are given in the table, because only slm values can be entered in the Pump Display
Terminal. To convert slm values to PA ls
-1
, multiply by (1.013/60) x 10
5
.
Table 8 - Electrics module default setpoints
Parameter Unit
Default setpoint values
Low alarm Low warning High warning High alarm
FDP pump temperature
°
CADJADJ75 85
FDP motor cooling-water return
temperature
°
C ADJ ADJ 55 ADJ
HMB1800 pump temperature
°
C ADJ ADJ 165 170
Exhaust gas temperature
°
C ADJ ADJ 220 ADJ
Table 9 - Gas module default setpoints: High gas configuration
Parameter Unit
Default Setpoints
Low Alarm Low Warning High Warning High Alarm
Dilution purge off slm 24 28.5 ADJ ADJ
Dilution purge on slm 30 35 ADJ ADJ
Inlet purge on slm 30 35 ADJ ADJ
Exhaust pressure psig ADJ ADJ 4.0 7.0
Shaft seals pressure psig ADJ ADJ 12.5 ADJ