© Edwards Limited 2009. All rights reserved. Page 33
Edwards and the Edwards logo are trademarks of Edwards Limited.
INSTALLATION
A533-23-880 Issue C
3.3 Unpack and inspect
The iF system is supplied sealed in a foil bag. To prevent contamination of the iF system, before you unpack and
inspect the iF system we recommend that you move the pallet as close as possible to the clean area in which you will
install the system. Remove the foil bag carefully; use the bag as a dust cover while you wheel the iF system to its
final operating position.
Use the following procedure to unpack and inspect the iF system.
1. Place the pallet in a convenient position with a fork-lift truck or a pallet truck.
2. Remove the staples which secure the cardboard box to the pallet, then remove the cardboard box. Open the top
of the foil bag which encloses the iF system.
3. Check that you have received the items listed in Table 12. If any of these are missing, notify your supplier within
three days.
4. Refer to Figure 14. Remove the nut and washer (2) which secures each of the four anchor brackets (5) to the
blocks (4) on the pallet. Retain the nuts and washers for future use.
5. Refer to Figure 15. Use suitable lifting-equipment attached to all four lifting bolts (1) to remove the iF system
from its pallet. Do not try to lift the iF system by hand (refer to Table 4 for the mass of the iF system).
6. Inspect the iF system. If the iF system or any other item is damaged, notify your supplier and the carrier in
writing within three days; state the Item Number of the iF system together with your order number and your
supplier's invoice number. Retain all packing materials for inspection. Do not use the iF system if it is damaged.
7. If the iF system is not to be used immediately, replace the packing materials. Store the iF system in suitable
conditions as described in Section 7. If you will use the iF system immediately, continue at Step 8.
8. Refer to Figure 14. If you do not want to use the anchor brackets to prevent inadvertent movement of the iF
system (refer to Section 3.5), undo and remove the two cap-head screws and washers (6) which secure each of
the four brackets (5) to the sides of the iF system, then remove the brackets. Retain the brackets, cap-head
screws and washers for future use.
You must use suitable lifting equipment to move the iF system. It is too heavy to lift by hand.
Ensure that the maximum angle between paired slings used to lift the iF system is 45
o
, and that all
four lifting bolts are used.
Do not exceed the topple angle of 10
o
when moving the pump.
Table 12 - Checklist of components
Quantity Description Check( )
1iF Dry Pumping System
1Pump Display Terminal
1 Fittings Kit, comprising:
1 Cooling-water quick-release connectors (pair)
1 NW40 tapped ’O’ ring