INSTALLATION
A533-23-880 Issue C
3. Ensure that the voltage select cable (7) is connected to the correct voltage terminal of the terminal-block (8)
for your electrical supply. Reconfigure if necessary.
4. Refit the cover (4) and secure with the two screws (5).
Table 13 - Pins in the iF Tool Interface Module connector plug
Pin(s) Use
1 and 2
3 and 4
5
6
Linked as supplied. Remove the link and connect these pins to your normally-
closed, isolated external emergency stop circuit.
Isolated auxiliary contacts of the emergency stop switch on the Electrics Box.
24 V a.c. continuous output; maximum current 625 mA
0 V return