E F A P O W E R E V - PC - I N S T A L L A T I O N A N D U S E R M A N U A L
34 | 37
8.1.1 BATTERY MAINTENANCE (IF APPLICABLE)
Normally the batteries are a sealed type, without need of any special maintenance. In any case, the actions must
be in accordance with the battery manual supplied in attachment.
IN CASE OF NO INPUT VOLTAGE, THE COMMAND SYSTEM OF THE EFAPOWER EV WILL STILL BE FED, WHICH
GUARANTEES IN THIS CASE COMMUNICATION FOR ALARM SENDING AND BILLING INFORMATION.
CHARGING THE CAR IS NOT POSSIBLE IN THIS CASE.
NEVER THROW USED BATTERIES IN NORMAL TRASH. THE SUPPLIER RETRIEVES THEM FOR RECYCLING
ACTIONS. WHEN HANDLING BATTERIES BEWARE OF HAZARDOUS CHEMICALS. IT IS RECOMMENDED THAT
ONLY QUALIFIED PERSONNEL HANDLE THEM.
DANS LE CAS DE NE PAS EXISTER TENSION D’ENTRÉE, LE SYSTÈME DE COMMANDE DU EFAPOWER EV CONTINUÉ D’ÊTRE
ÉLECTRIQUEMENT ALIMENTÉ, QUI DANS CETTE CAS EST GARANTIT QUE LES ALARMS ET LA FACTURATION VONT ÊTRE
COMMUNIQUÉ AUX LOGICIEL DE SUPERVISION. DANS CE CAS LE CHARGEMENT DE LA VOITURE N’EST PAS POSSIBLE.
NE JAMAIS JETER LES BATTERIES A FIN DE VIE DANS POUBELLE NORMAL. LE FOURNISSEUR LES VA RÉCUPÈRE POUR
RECYCLAGE. LORSQUE LA MANIPULATION DES BATTERIES EST CONSIDÉRÉE DANS LA GAMME DES PRODUITS CHIMIQUES
DANGEREUX. IL DEMANDE DU PERSONNEL QUALIFIÉ POUR LES MANIPULER.
8.2 TROUBLESHOOTING
ALL SERVICING MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL. DO NOT ATTEMPT TO SERVICE THE
EFAPOWER EV-PC STATION YOURSELF.
DO NOT OPEN THE DOOR WHILE THE EFAPOWER EV-PC STATION IS ENERGIZED.
BY OPENING THE DOOR OF THE EFAPOWER EV-PC STATION YOU RUN THE RISK OF EXPOSURE TO
DANGEROUS VOLTAGES!
TOUS LES SERVICES DOIVENT ETRE EFFECTUES UNIQUEMENT PAR DU PERSONNEL QUALIFIE. NE PAS TENTER DE REPARER
L’EFAPOWER EV-PC VOUS-MEME.
EN OUVRANT LES PORTES DE L’EFAPOWER EV-PC VOUS COUREZ LE RISQUE D'EXPOSITION AUX TENSIONS DANGEREUSES!
We advise to carry out the following verifications:
Table 7 - EFAPOWER EV-PC Troubleshooting (Part 1)
LED
Description
Cause
Action
--
All LEDs are off
No energy supply
Verify the existence of grid voltage
Verify if the circuit breaker on the
main distribution board and the
dedicated circuit to the charge are
both switched ON
Faulted LEDs
Replace LEDs
EFAPOWER EV-PC
signals fault
The differential circuit
breaker of the Unit is
switched off
Disconnect any connection to the
vehicle
Verify cable and connector/socket
damage
If the connection is OK, then switch
ON the circuit breaker
If the problem persists, please contact
the technical support team
End of charge caused by a
fault, or cable removed from
the vehicle side.
Verify cable and connector/socket
damage
If the problem persists, please contact
the technical support team
No communication between
Central Unit and ouput
controller
If the problem persists, please contact
the technical support team

Related product manuals