E F A P O W E R E V - PC - I N S T A L L A T I O N A N D U S E R M A N U A L
21 | 37
6 START-UP
6.1 VERIFICATION AND INSPECTION
Check if the bolts of the AC and protective ground cables of the EFAPOWER EV-PC Station are correctly
tightened
Check the resistance between the EFAPOWER EV-PC protective ground and the low voltage switchboard
ground connection; the value must be according to local codes and should follow the NEC (National
Electrical Code) or the CEC (Canadian Electrical Codes) accordingly.
Before switching ON all the fuses and circuit breakers, check the supply voltage between lines, which
depending on the unit configuration, must be:
- Three phase for CE and GB marked Units - 400V ± 10% 50Hz
- Single phase for ETL marked Units - 208V/240V ± 10% 60Hz
At this stage, whenever the Unit shall be integrated with a Network Management System, Efacec must
already have the following information:
For Unit configuration: Station(s) ID and Central Management Endpoint
For Router configuration: APN and PIN, Username and Password (if applicable)
6.2 SWITCH ON
BEFORE ATTEMPTING TO INSTALL OR START UP THE EFAPOWER EV-PC STATION THE USER MUST ENSURE
THAT THE SAFETY INSTRUCTIONS IN THIS MANUAL HAVE BEEN CAREFULLY READ AND OBSERVED BY
TECHNICALLY COMPETENT PERSONNEL.
KEEP THIS MANUAL WITH THE EFAPOWER EV-PC STATION FOR FUTURE REFERENCE.
THIS EFAPOWER EV-PC STATION MUST NOT BE STARTED OR PUT INTO USE WITHOUT HAVING BEEN
COMMISSIONED BY A FULLY TRAINED AND AUTHORIZED PERSON.
AVANT D'INSTALLER OU LA MISE EN EFAPOWER EV-PC STATION L'UTILISATEUR DOIT ASSURER QUE LES INSTRUCTIONS DE
SECURITE DANS CE MANUEL SONT LIRE ATTENTIVEMENT ET OBSERVER PAR UN PERSONNEL TECHNIQUE COMPETENT.
CONSERVER CE MANUEL AVEC L’EFAPOWER EV-PC STATION POUR FUTURE REFERENCE.
CETTE EFAPOWER EV-PC STATION NE DOIT PAS ETRE COMMENCE OU MIS EN UTILISATION SANS AVOIR ETE RANG PAR UNE
PERSONNE FORME ET AUTORISE.
ALL SERVICING MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL. DO NOT ATTEMPT TO SERVICE THE
EFAPOWER EV-PC STATION YOURSELF.
DO NOT OPEN THE DOOR WHILE THE EFAPOWER EV-PC STATION IS ENERGIZED.
BY OPENING THE DOOR OF THE EFAPOWER EV-PC STATION YOU RUN THE RISK OF EXPOSURE TO DANGEROUS
VOLTAGES!
IN CASE OF ANY KIND OF DOUBT REGARDING THESE INSTRUCTION, PLEASE CONTACT:
TOUS LES SERVICES DOIVENT ETRE EFFECTUES UNIQUEMENT PAR DU PERSONNEL QUALIFIE. NE PAS TENTER DE REPARER
L’EFAPOWER EV-PC VOUS-MEME.
EN OUVRANT LES PORTES DE L’EFAPOWER EV-PC VOUS COUREZ LE RISQUE D'EXPOSITION AUX TENSIONS DANGEREUSES!
EN CAS DE DOUTE CONCERNANT CE, CONTACTER:
EFACEC WILL ASSUME NEITHER RESPONSIBILITY NOR LIABILITY DUE TO INCORRECT OPERATION OR
MANIPULATION OF THE EFAPOWER EV-PC STATION.
Rua Eng.º Frederico Ulrich - Apartado 3078
4471-907 MOREIRA MAIA - PORTUGAL
Tel: (+351) 229403241 - Fax: (+351) 229403209
serviceEEM@efacec.com
www.electricmobility.efacec.com
2725 Northwoods Parkway, Ste. B
Norcross, Georgia 30071 USA
Tel: (1) 470 395-3648 -
Fax: (1) 770 446 8920
support.eem.usa@efacec.com
www.electricmobility.efacec.com

Related product manuals