EFI VUTEk 5r Series - 4.6 Clean the ionizer bars.

Default Icon
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Every 8 Hours
Document ID: OMM-00144-L VUTEk 3r & 5r Series Maintenance Guide 31
PPE Items: GLOVES NITRILE DISPOSABLE BOX LARGE
SAFETY GLASSES
Required Items: ISOPROPYL ALCOHOL (IPA)
PLASTIC CLEANING BRUSH
How-to Video:
Directions:
1. Move the carriage to the top position (35mm).
2. Open the printer hood and insert the retaining pins into the LH and RH pin sockets.
3. Apply IPA to the brush bristles and brush the underside of each of the ionizer bars, Figure 4-13
.
4. Remove the retaining pins after completing tasks.
4.6 Clean the ionizer bars.
CLICK TO PLAY
Figure 4-13 Brushing Ionizer Bars