Instruction Manual
7.8.6.1 Setting the Speed Limitation Depending on High Lift
NOTE
The setting of the speed limitation depending on high lift is necessary compelling by application of a new or a
new formatted top part detection module (OTE module).
Otherwise the machine speed limitation depending on high lift set with parameter 117 is in effect.
Besides, in the display of the operating device the tip is indicated – Poti – .
Every mechanical change of the potentiometer likewise requires this setting.
Parameter 501 is used to program the value for the minimum lift, and 502 for the maximum lift.
Proceed as follows:
Set the handwheel for a high lift for walking foot of 0 (minimum lift)
Select parameter 501! Set the handwheel for a high
lift for walking foot of 5 (minimum lift)
Potentiometer value currently 112, with 110 stored
Potentiometer value 112 taken
Set the handwheel for a high lift for walking foot of 5
(maximum lift)
Next parameter displayed: potentiometer value
currently 120, with 118 stored
Potentiometer value 120 taken
Next parameter is displayed. Speed Limitation Depending
on High Lift (0 0 deactivated, 1 = activated
7.9 Speed Limitation n9
Function with or without control panel
When a key is pushed to which input function 33 is assigned, speed limitation n9 is activated. The speed is
controlled by the pedal up to the limit.
7.10 Speed Limitation n11 with Signal Output M10 / flip flop 2)
Function with or without control panel
Speed limitation n11
Disabling of flip-flop functions at the seam end On/Off
Function "speed limitation n11" inverted/non-inverted
Function of signal M10 on socket ST2/29 after “power on”
The speed limitation can be switched on by pressing a key on any of the inputs in1...i10 and switched off by
pressing the key again. A signal output which can be programmed individually (inverted/non-inverted) is
provided for the speed limitation. Furthermore, the function of signal output M10 can be determined after "power
on".