Instruction Manual
6.9.1 Setting the Reference Position (Parameter 270 = 0 or 6)
The angular positions necessary on the machine e.g. "needle down position" or "thread lever up position" are
stored in the control. A reference position is needed in order to establish a relationship between position
transmitter information and actual mechanical position.
The reference position must be set:
for initial operation
after replacing the motor
after replacing the microprocessor
Setting the reference position on the control
Input code number and select parameter 170!
P o (character o rotating)
Turn handwheel until rotating character
o goes off on the display.
By turning the handwheel, set the
needle to the bottom dead center or the
needle point to the height of the needle
plate in the direction of rotation of the
motor shaft, while needle is moving
downward.
Configuration of the zero point of the machine
actual parameter number is displayed
Exit programming at the technician level.
Setting the reference position on the V810 control panel
Input code number and select parameter 170!
PoS0 o (character o rotating)
Turn handwheel until rotating character
o goes off on the display.
Set the needle to the bottom dead
center by turning the handwheel.
Configuration of the zero point of the machine
actual parameter number is displayed
Exit programming at the technician level.
Setting the reference position on the V820/850 control panel
Input code number and select parameter 170!
PoS0 o (character o rotating)
Turn handwheel until rotating character
o goes off on the display.
Set the needle to the bottom dead
center by turning the handwheel.
Configuration of the zero point of the machine
actual parameter number is displayed
Exit programming at the technician level.
If error message A3 (reference position not set) appears, repeat the above setting sequence!
6.9.2 Setting the Positions on the Control (Parameter 270 = 0 or 6)
Do these settings whenever the encoder incorporated in the motor is used (parameter 270 = 0), or a position
transmitter mounted on the machine head (e.g. IPG pulse encoder or HSM Hall sensor) (parameter 270 = 6),
whose preset values must be adapted.
Input code number and select parameter 171.
P1E is displayed; set "position 1 On" on the handwheel
P2E is displayed; set "position 2 On" on the handwheel
P1A is displayed; set "position 1 Off" on the handwheel
P2A is displayed; set "position 2 Off" on the handwheel
Exit programming at the technician level.