3.3 Specifications
Performance data
Product
EFOY Pro
800
EFOY Pro
800 Duo
EFOY Pro
2400
EFOY Pro
2400 Duo
Max. rated output
45 W
45 W
110 W
110 W
Min. power output
1
25 W
25 W
80 W
80 W
Nominal voltage
12 V / 24 V (Lead batteries)
Max. charging current
3.75 A /
1.88 A
3.75 A /
1.88 A
9.17 A /
4.58 A
9.17 A /
4.58 A
Min. nominal charging
current at 12 V / 24 V
1
2.1 A /
1.05 A
2.1 A /
1.05 A
6.7 A /
3.3 A
6.7 A /
3.3 A
Recommended battery
capacity
2
at 12 V
at 24 V
40 - 160 Ah
10 - 100 Ah
40 - 160 Ah
10 - 100 Ah
60 - 350 Ah
30 - 175 Ah
60 - 350 Ah
30 - 175 Ah
Switching thresholds
for automatic battery
charging at 12 V / 24 V
3
On: <12.3 V / <24.6 V
Off: >14.2V / >28.4 V
Required starting volt-
age at 12 V /24 V
>9 V / >18.5 V
Max. batteriy voltage at
12 V / 24 V
16 V / 30,5 V
(Anti freeze mode up to 17 V / 32 V)
Nominal consumption
4
0.9 l/kWh / 0.2 gallons/kWh
Quiescent power con-
sumption
20 mA
1
Nominal power varies by ±10 %, decreases linear with the operation hours. Specification valid
within warranty period.
2
Depends on battery type and application - bigger batteries possible if
charging current sufficient for battery (e.g. solar batteries).
3
Factory setting - can be modified with interface adapter and PC.
4
Effective consumption depends on operating conditions.