Page #8 background imageLoading...
Page #8 background image
8
About the Monitor
About the Monitor
Indications for Use
This product is intended to be used to display medical images, such as endoscopic surgery images.
Attention
This product is not intended for diagnostic purposes.
This product should be set to horizontal view mode.
This product may not be covered by warranty for uses other than those described in this manual.
The specications stipulated in this manual are only applicable when the enclosed power cord is used.
Only use optional products manufactured or specied by us with this product.
Precautions for Use
Parts (such as the LCD panel and the fan) may deteriorate over extended periods of time. Periodically
check that they are operating normally.
When the screen image is changed after displaying the same image for extended periods of time, an
afterimage may appear. Use the screen saver or power save function to avoid displaying the same
image for extended periods of time. An afterimage may appear even after a short period has elapsed
depending on the displayed image. If this occurs, changing the image or leaving the power o󰀨 for a few
hours may solve the problem.
If the monitor displays continuously over a long period of time, dark smudges or burn-in may appear. To
maximize the life of the monitor, we recommend the monitor be turned o󰀨 periodically.
The backlight of the LCD panel has a xed lifetime. When the screen becomes dark or begins to icker,
please contact your local EIZO representative.
The screen may have defective pixels or a small number of light dots on the screen. This is due to the
characteristics of the panel itself, and is not a malfunction of the product.
Do not press on the panel or edge of the frame strongly, as this may result in display malfunctions, such
as interference patterns, etc. If pressure is continuously applied to the panel surface, it may deteriorate
or damage it. (If the pressure marks remain on the panel, leave the monitor with a black or white screen.
The symptom may disappear.)
Do not scratch or press on the panel with any sharp objects, as this may result in damage to the panel.
Do not attempt to brush with tissues as this may scratch the panel.
Condensation may form on the surface or interior of this product when it is brought into a cold room,
when the temperature suddenly rises, or when it is moved from a cold room to a warm room. In that
case, do not turn the monitor on. Instead wait until the dew condensation disappears, otherwise it may
cause some damage to the monitor.
It takes about 30 minutes for the monitor display to stabilize. Before using the monitor, wait 30 minutes
or longer after the monitor power has been turned on or after the monitor has recovered from the power
saving mode.

Other manuals for Eizo CuratOR EX3242-3D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eizo CuratOR EX3242-3D and is the answer not in the manual?

Eizo CuratOR EX3242-3D Specifications

General IconGeneral
BrandEizo
ModelCuratOR EX3242-3D
CategoryMonitor
LanguageEnglish

Related product manuals