TECHNICAL DATA
06/2020 23 NP-DK50 2V 50, 2x2V 110-A-5_06-2020-MD
Working pressure 6 8
bar
DK50 2x2V/110
DK50
2x2V/110S
DK50
2x2V/110/M
DK50 2x2 V/110
S/M
Nominal voltage
Frequency
a)
V, Hz
230,50
3x400,
50
230,60
115,60
230,50
3x400,
50
230,60
115,60
230,50
3x400,
50
230,60
115,60
230,50
3x400,
50
230,60
115,60
Capacity at 6 bar
(FAD)
l/min
270
270
215
215
Working pressure
b)
bar
6.0 8.0
6.0 8.0
6.0 8.0
6.0 8.0
Max. current
A
16.7
5.8
17.1
6.2
16.8
5.9
17.2
6.3
Motor power
kW
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
Air tank volume
l
110
110
110
110
Air quality
filtration
m
-
-
0.3
0.3
Maximum
operating
pressure of safety
valve
bar
9.0
9.0
9.0
9.0
Noise level at 5
bar (L
pA
)
dB
≤73
≤55
73
≤56
Operating mode
%
S1-100
S1-100
S1-100
S1-100
PDP drying at 7
bar
°C
-
-
+3
+3
Tie to fill air tank
from 0 to 6 bar
s
159
159
198
198
Dimensions (net)
w x d x h
mm
1085x490x815
1200x725x992
1085x625x815
1200x725x992
Net weight
kg
106
104
177
175
113
111
184
182
a)
State the compressor variant in the order
b)
For other range of pressure consult with the supplier
c)
Weight value is only informative data and applies only to a product without any accessories
Dependence of compressor capacity on working pressure

Table of Contents

Other manuals for EKOM DK50 2V/50

Related product manuals