EasyManua.ls Logo

EKOM DK50 2V/50 - Page 24

EKOM DK50 2V/50
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DATA
NP-DK50 2V 50, 2x2V 110-A-5_06-2020-MD 24 06/2020
Working pressure 8 10
bar
DK50 2x2V/110
DK50
2x2V/110S
DK50 2x2V/110/M
DK50 2x2 V/110
S/M
Nominal voltage
Frequency
a)
V, Hz
230,
50
3x400,
50
230,60
115,60
230,5
0
3x400
,50
230,60
115,60
230,50
3x400,5
0
230,60
115,60
230,50
3x400,
50
230,60
115,60
Capacity at 8 bar
(FAD)
l/min
210
210
165
165
Working pressure
b)
bar
8.0 10.0
8.0 10.0
8.0 10.0
8.0 10.0
Max current
A
16.5
5.2
16.9
6.6
16.6
6.3
17.0
6.7
Motor power
kW
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.2
2x1.2
2x1.1
Air tank volume
l
110
110
110
110
Air quality
filtration
m
-
-
0,3
0,3
Maximum
operating
pressure of safety
valve
bar
12.0
12.0
12.0
12.0
Noise level at 5
bar (L
pA
)
dB
≤73
≤55
73
≤56
Operating mode
%
S1-100
S1-100
S1-100
S1-100
PDP drying at 7
bar
°C
-
-
+3
+3
Time to fil air tank
from 0 to 6 bar
s
256
256
-
-
Dimensions (net)
w x d x h
mm
1085x490x815
1200x725x992
1085x625x815
1200x725x992
Net weight
kg
110
108
181
179
117
115
188
186
a)
State the compressor variant in the order
b)
For other range of pressure consult with the supplier
c)
Weight value is only informative data and applies only to a product without any accessories
Dependence of compressor capacity on working pressure

Table of Contents

Other manuals for EKOM DK50 2V/50

Related product manuals