MAINTENANCE
18 SM-DK50 DS-EN-20_02-2016
Maintenance replacement parts
When performing routine service, the manufacturer recommends the
following replacement parts that may be ordered separately:
Cylinder fitting Part No. 023000239-000
Bearing removeal tool 6204 Part No. 604001094-000
Pressure gauge set Part No. 191000007-000
Hose with valve Part No. 191000008-000
Flow meter set Part No. 191000009-000
Safety valve check
The safety valve is adjusted to 7 bar by the manufacturer, then tested
and marked. It must not be readjusted!
Only allow the safety valve freely
puff for a short period of time.
Never use the safety valve to release pressure in the air tank. This could
damage the safety valve.
Check tightness of joints and inspect the equipment
Test for leakage:
Disconnect the outlet hose from the quick coupling OUT (9); compressed
air consumption will stop.
Pressurize the air tank by releasing some air via a connected device.
With the compressor off, wait at least 10 minutes before checking the
pressure level.
If the pressure has dropped, use soapy water to find the leaky joint. Start
with the joints outside the case, and then test the ones inside the case
after removing the covers.
Tighten or re-seal joints as necessary.
Inspect the equipment:
Clean and vacuum the interior of the cabinet.
Check the status of the compressor motor for balanced operation or noise.
Check the condition of the hangers above the pump.
Check fan functionality.