96 / EN
User Menu
The holiday function is activated. The system will
automatically turn on again at hours 00:01 of the
day 30/12/2021. The antifreeze function is active.
Fig. 44
A message will appear to confirm the settings.
Operation mode
Allows for selecting the system’s operating mode:
– "Summer": domestic hot water production, space heat-
ing off.
– "Winter": domestic hot water production and space heat-
ing on.
– "Heating only": indirect cylinder heating off (where pres-
ent).
– “Cool mode and Domestic hot water“: domestic hot
water production and cooling.
– “Only Cool mode“: indirect cylinder heating off (where
present).
– "OFF": system off, anti-frost function enabled.
DHW settings
The “DHW settings” function allows for selecting:
– The desired water temperature.
– The operating mode for domestic hot water production.
– The thermal sanitisation function for the DHW storage tank
(if present).
DHW settings
DHW comfort setpoint temp.
55°C
DHW reduced setpoint temp. 35°C
Comfort function Disabled
Tank charge mode Standard
Domestic hot water boost
>
Thermal cleanse function
>
Fig. 45
– "DHW comfort setpoint temp.": setting of the tempera-
ture set-point for the comfort slot.
– "DHW reduced setpoint temp.": setting of the tempera-
ture set-point for the reduced-temperature slot.
– "Comfort Function": setting of the operating mode
for domestic hot water production (“Disabled”/”Time
Based”/”Always active”).
– "Tank charge mode": setting of the cylinder filling mode
in hybrid systems (“Standard”/”Fast”).
– "Domestic hot water boost": fast filling of the cylinder
(available for heating heat pumps and domestic hot wa-
ter).
– "Thermal cleanse function": see next paragraph.
– "DHW time program": direct access to the DHW time
scheduling menu.