EasyManua.ls Logo

ELECTRO FREEZE 812 - Slush Freezer Troubleshooting Chart

ELECTRO FREEZE 812
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Slush Freezer
Troubleshooting Chart
TURN WATER
SUPPLY ON IF
OFF
REPOSITION
WATER LINES
IF KINKED
CHECK TO
SEE IF TOP
TORQUE
SPRING IS
ATTACHED
OPERATOR COMPLAINT IS:
“PRODUCT WILL NOT FREEZE”
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF
A
IR
COOLED
CHECK FOR
AIR INTAKE/
DISCHARGE
BLOCKAGE
IF WATER
COOLED
CHECK
FOR WATER
FLOW
BLOCKAGE
PRECOOL
PRODUCT
WARM
PRODUCT
WILL
RESULT IN
SLOW
RECOVERY
OPERATOR COMPLAINT IS:
“POOR OR SLOW PRODUCT RECOVERY
CHECK
SCRAPER
BLADES
IF WORN
REPLACE
CHECK
FREEZER
CAPACITY
RATING
DISPENSING
TOO LARGE
OF VOLUME
A
T ONE TIME
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF
A
IR
COOLED
CHECK FOR
AIR INTAKE/
DISCHARGE
BLOCKAGE
* ON FREEZERS WITH AUTO-FILL SYSTEM, BRIX FILL STATION TO PRODUCT SUPPLIERS RECOMMENDATION (MINIMUM 11% BRIX).
MOVE
OBSTRUCTION
OR MOVE
FREEZER
MUST HAVE
AT LEAST 6"
CLEARANCE
MOVE
OBSTRUCTION
OR MOVE
FREEZER MUST
HAVE AT LEAST
6" CLEARANCE
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRI
X
*
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRIX*
184262