EasyManua.ls Logo

ELECTRO FREEZE 812 - Freezer Vibrates or Rocks Excessively; Product Is too Thick; Will Not Dispense

ELECTRO FREEZE 812
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Slush Freezer
Troubleshooting Chart
* ON FREEZERS WITH AUTO-FILL SYSTEM, BRIX FILL STATION TO PRODUCT SUPPLIERS RECOMMENDATION (MINIMUM 11% BRIX).
CHECK TO SEE
IF BOTTOM
TORQUE
SPRING IS
ATTACHED
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRI
X
*
CHECK MIX SUPPLY
KEEP HOPPER FILLED MUST
BE ABOVE
1/3 FULL
MAKE SURE
ADJUSTMENT
SCREW IS IN LINE
WITH TORQUE
SWITCH
OPERATOR COMPLAINT IS:
“PRODUCT IS TOO THIC
” or "WILL NOT DISPENSE"
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
OPERATOR COMPLAINT IS:
“FREEZER VIBRATES OR ROCKS EXCESSIVELY”
CHECK MIX
SUPPLY
KEEP HOPPER
FILLED
MUST BE ABOVE
1/3 FULL
CHECK PRODUCT
BRIX ADJUST TO
11-13% BRIX*
CHECK
SCRAPER
BLADES
IF WORN
REPLACE
CHECK TO
SEE IF
FREEZER IS
LEVEL AND
ALL 4
CASTERS
ARE
ADJUSTED
PROPERLY
TURN ADJUSTMENT SCREW
¼ TURN CLOCKWISE
WAIT 30 MINUTES
RECHECK

Table of Contents