34 en | Recommended configurations ZLX-G2 Full-range loudspeaker
2023-10 | 01 |
User manual
Bosch Security Systems, LLC
!
Caution!
Do not exceed the maximum load rating of the amplifier.
Amplifier Load (per Output Channel)
# of Speakers Nominal Minimum
1 8 Ohms 7.2 Ohms
2 4 Ohms 3.6 Ohms
3 2.7 Ohms 2.4 Ohms
4 2 Ohms 1.8 Ohms
9.2.2 Using full-range systems as stage monitors
The configuration includes:
Multiple ZLX-8-G2, ZLX-12-G2 or ZLX-15-G2 loudspeakers in monitor position.
Dynacord L1800FD amplifier programmed with the appropriate speaker settings from
SONICUE.
Input A
Input B
Output A
Output B
NL4 Pin Configuration
Pin 1+ and 1- Used
Pin 2+ and 2- Not used
!
Caution!
Do not exceed the maximum load rating of the amplifier.
Amplifier Load (per Output Channel)
# of Speakers Nominal Minimum
1 8 Ohms 7.2 Ohms
2 4 Ohms 3.6 Ohms
3 2.7 Ohms 2.4 Ohms
4 2 Ohms 1.8 Ohms