Procedure for use
4758 A
Calibration mode/normal mode
To gain access to the calibration switch in the sca-
le unit, the top panel has to be taken off. Remove
the four screws on the scale unit cover. Then the
calibration switch can be switched between nor-
mal mode ”ON” and calibration mode ”CAL”.
ON (normal) CAL (calibration)
Calibration
switch
Scale unit
Calibrate the scale
Press b five times to
highlight ”CALIBRATE
THE SCALE”.
Press SELECT.
Press SELECT.
Set the calibration
switch to calibra-
tion mode.
Press SELECT.
Please note:
The machine must be unladen at the start of cali-
bration, i.e. no water or wash load in the drum.
Please note:
This function is used only on installation of a new
scale unit.
For machines with weighing equipment installed only!
Calibrate the scale
If this calibration has not succeeded you will see
an error message equivalent to: “FAILED. PRESS
SELECT” on the display. For troubleshooting, see
the section “Fault-finding, weighing equipment” in
the machine manual.
4780
SERVICEPROGRAM
MAKE A CHOICE:
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SETTARETOACERTAINVALUE
READTAREVALUE
CALIBRATE THE SCALE
SELECT
RESET SCALE TO ZERO
RESET TARE TO ZERO
TARE SCALE
SETTARETOACERTAINVALUE
READTAREVALUE
CALIBRATE THE SCALE
ZERO CALIBRATION
READVERSIONNUMBER
EXIT
SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
PLEASE SET SCALE TO
CALIBRATION MODE
PRESS SELECT
FOR ZERO CALIBRATION
SELECT
SELECT
3588
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
DONE! PRESS SELECT
SELECT
SELECT
3588