54
Alarm Description Possible fault Machine status/action Reset
E83
Error in reading selector Main PCB faulty (Incorrect configuration data). Cycle cancelled START/RESET
E86
Selector configuration error Display board. ----------------
START
ON/OFF
RESET
E87
Display board microprocessor faultyDisplay board.
No action to be performed, if continues,
replace the display board.
START
ON/OFF
RESET
E91
Communication error between main
PCB and display
Wiring faulty; Control/display PCB faulty; Inverter board faulty; Weight
sensor board faulty, ED PCB faulty, Main PCB faulty.
---------------- RESET
E92
Communication inconsistency
between main PCB and display
(incompatible versions)
Incorrect control/display PCB;
Incorrect PCB (does not correspond to the model).
Cycle blocked. ON/OFF
E93
Appliance configuration error Main PCB faulty (incorrect configuration data). Cycle blocked. ON/OFF
E94
Incorrect configuration of washing
cycle
Main PCB faulty (incorrect configuration data). Cycle blocked. ON/OFF
E97
Inconsistency between programme
selector and cycle configuration
Main PCB faulty (incorrect configuration data). Cycle blocked. RESET
E98
Communication error between main
PCB - Inverter
Incompatibility between main PCB and Inverter. Cycle blocked. ON/OFF
E9C
Display board configuration error Display board faulty. ----------------
START
ON/OFF
RESET
E9E
Display board sensor/touch key
faulty
Display board faulty. ---------------- ON/OFF
EC1
Electronically controlled valve
blocked with operating flowmeter
Faulty cabling; Faulty/blocked solenoid, PCB faulty.
Cycle stops with door locked.
Drain pump continues to operate (5 min.
on, then 5 min. off. etc.).
RESET
EF1
Drain filter clogged
(drain phase too long)
Drain filter clogged/dirty;
Drain hose blocked/kinked/too high.
Warning displayed at the end of cycle. START/RESET
EF2
Overdosing of detergent
(too much foam during drain
phases)
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Warning displayed after 5 attempts. RESET
EF4
Water fill pressure too low, no signal
from flowmeter and electronically
controlled valve is open
Tap closed, water fill pressure too low. ---------------- RESET
EF5
Unbalanced load Final spin phases skipped. ---------------- START/RESET
EF6
Reset If it continues, replace the main board. No action to be taken. ----------------
EH1
Supply frequency of appliance
outside the limits
Problem with the power supply network (incorrect/disturbed); Main
PCB faulty.
Wait for nominal
frequency conditions.
ON/OFF