17
DE
DD52R-E (GN 9053)
-
DD52R-E-RF (GN 9153)
Modelle, alle Rechte vorbehalten in Übereinstimmung mit dem Gesetz.
Bei Reproduktion der Zeichnungen, bitte immer Quellenangabe.
8.2 Device parameters (in alphabetical order)
Parameter Description Available options Default
dir
Measurement
direction
Set direction of the
positive axis
--o
counterclockwise rotation
to increment the measure
o--
clockwise rotation to
incrememnt the measure
--o
diSPL
Display orientation
0°
180°
180°
OFFSET
Offset Value
See cap. 8.5
The system allows to store up to
10 compensation values:
OFS 0
...
OFS 9
0.0
OriGin
Reference value
displayed at the
starting point
See cap. 8.5
0.0
P_toll
Tolerance of target
position
mm:
0.01
÷
9.99
inches:
0.001
÷
0.393
degrees:
0.01
÷
9.99
The parameter value depends
on the unit of measure selected.
mm:
0.10
inches:
0.004
Degree:
0.10
rAdio
Wireless
transmission
parameters
nEt id: id00 ÷ id99
nEt ch: ch01 ÷ ch36
id 00
ch01
rES
The parameter
allows to defin the
resolution of the
measure
mm:
1
;
0.1
;
0.01
inches:
1
;
0.1
;
0.01
;
0.001
degrees:
1
;
0.1
;
0.01
mm:
0.1
inches:
0.01
degrees:
1
SPEEd
The parameter set
the maximum speed
of the movement
in rpm that can be
correctly read
300
;
600
;
1000 600
StEP
Reading
after one revolution
0.01
;
100.00
001.00