Smart ZB Thermostat 16 A
Guard temperature
To set the maximum and minimum guard temperature:
• On setting page, tap Max Guard Temperature (D) to set upper temperature
limit of the floor sensor and then tap Save.
NOTE: The temperature ranges form 5°C to 19°C and maximum guard
temperature should be higher than minimum guard temperature
• Tap Min Guard Temperature (E) to set lower temperature limit of the floor
sensor and then tap Save.
NOTE: The temperature ranges form 21°C to 40°C and minimum guard
temperature should be lower than maximum guard temperature
Valve protection settings
Hydronic underfloor heating and boiler connections require valves and protection,
while electric underfloor heating does not use valves. This feature can only be
used in hydronic applications.
Valve protection
The valve protection can be enabled or disabled by tapping the toggle switch (A)
on the valve protection setting.
NOTE: Activate output every two weeks to prevent valve calcification. It only
supports Enable/Disable feature.
Temperature Detection
Active Brightness Level
Screen Active Duration
Idle Brightness Level
Air Temperature
1 Min(s) 0 Sec(s)
100%
Screen Brightness Settings
Sensors Settings
Settings
Temperature Calibration
Valve Protection
Valve Protection Settings
Child Lock
Child Protection Settings
100%
? +0.1 C
A
22 DUG_ZB Thermostat 16 A_ELKO-00