10. parameter reference
The parameter reference lists all the parameters alphabetically and describes each parameter in full.
The parameters are also listed in the following groups:
• Function: groups the parameters by functionality such as product temperature, defrost, and so on.
• Owners: groups the parameters by organization, such as OEM,responsible for defining the parameter values.
The parameter values vary between different cooler types, cooler characteristics, operating environments, brand
requirements, and operational preferences.
Parameter settings are defined by customers - OEMs, Bottlers and Brands - using an XML request form, and
supplied in the relevant parameter information (PI) provided by elstat.
10.1 Parameters by function
The table below details the parameters grouped by function
TEMPERATURE
Celsius or Fahrenheit (CF)
Set point (SP) and differential (dIF)
Saving set point (SSP) and saving differential (Sd)saving temperature disable (PEr)
Appliance sensor: calibration 1 (CA1)
OPERATION
Saving restart (Sr)
Delay to saving mode (dS)
Freeze-up protection (dtt)
Compressor rest time (rt)
DEFROST
Defrost method (dF) and defrost termination method (dtF)
Defrost interval (dE) and defrost duration (dd)
Defrost activation temperature (ddt) and defrost termination temperature (dtd)
Defrost heater (dHr)
Evaporator sensor: calibration 2 (CA2)
SELF-LEARNING Learning period (LP) and activity frequency (AF)
DISPLAY Display (dIS) and display stability (d2)
LIGHTS Light delay (Ld) and marketing mode (Ar)
EVAPORATOR FAN
Fan set point (FSP)
Fan cycle on (FCO) and fan cycle off (FCF)
ALARMS
Alarm delay (Ad)
Buzzer enable (b0) and buzzer duration (b1)
Refrigeration system failure (Ct)
Condenser high temperature (Ht) Not used on CO2 (R744) coolers
Note
Some parameters are not included with certain controllers. Please referto the to User Guide to
confirm which parameter set the controller has available.