7.10 Statistics
ems controllers start gathering statistics when first powered up.
Statistics provide information on the following:
Temperature: lowest, highest, and average temperature measured on the appliance sensor
Activity: average number of motion counts and door openings
Compressor: average number of compressor cycles and total compressor runtime
Operation: settings of the activity frequency (AF) parameter and the saving temperature disable (PEr)
parameter
Note
A full reset clears all the gathered statistics.
Not all controllers allow statistics to be viewed - the ems25+ is teach enabled and therefore
does not display statistics.
7.11 How to view statistics
To view the statistics, press the up and down buttons simultaneously.
Statistics include door opening, average temperatures and activity counts.
The ems controller then scrolls through the statistics pausing for 20 seconds at each statistic before returning to
normal operation.
The 3-digit display can show values from 000 to 999. For values of 1000 and above, the display shows the value as a
rounded decimal number. For example, 1.1 represents 1100, 1.2 represents 1200, and so on.
DISPLAY STATISTIC
DESCRIPTION PRIOR TO
JULY 2012
DESCRIPTION POST
JULY 2012
Activity frequency
Value of the activity frequency
AF parameter.
Possible values are: 0, 1, 2 or 3. (0
= low, 2= highand3 = automatic)
No change.
Average
temperature
Average temperature measured
by the appliance sensor during
the last 24 hours.
No change.
Compressor cycles
Average number of compressor
cycles per day (24 hour period)
during the past 7-days (7 x24
hour periods). Note that the
average is a moving average.
Total number of compressor
cycles since first powered up or
last full reset.
Compressor
runtime
Total number of hours thatthe
compressor has run since the
ems controller was first powered
up or since the last full reset.
No change.