23
www.elstat.io
For more informationaboutthe parameters usedinself-learning:
• See ”activity frequency (AF)”
• See ”learning period (LP)”
6.1 What is the self-learning matrix?
The self-learning matrix is a 7-day (7 x 24-hour), matrix with each 24-hour period divided into 48 30-minute periods.
Each 30-minute period has a state that ems controllers use to determine the mode as follows:
• 0 indicates no activity: ems controllers normally run in the saving mode
• 1 indicates a change in activity: ems controllers run in the ready mode
• 2 indicates activity: ems controllers run in the ready mode
For example, the self-learning matrix below shows the following:
• Day 1 to day 3: the ems controller runs in the ready mode from 06:00 to 18:00
• Day 4 and day 5: the ems controller runs in the ready mode from 06:00 to 20:00
• Day 6: the ems controller runs in the ready mode from 08:00 to 14:00
• Day 7: the ems controller remains in the saving mode.
Note
The self-learning matrix starts the moment the ems controller is first switched on and is not
synchronized with calendar days. However, the diagram below starts at 00:00 on Day 1 for
clarity