EasyManuals Logo

Elstat ems25 Series User Manual

Elstat ems25 Series
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
23
www.elstat.io
For more informationaboutthe parameters usedinself-learning:
See ”activity frequency (AF)”
See ”learning period (LP)”
6.1 What is the self-learning matrix?
The self-learning matrix is a 7-day (7 x 24-hour), matrix with each 24-hour period divided into 48 30-minute periods.
Each 30-minute period has a state that ems controllers use to determine the mode as follows:
0 indicates no activity: ems controllers normally run in the saving mode
1 indicates a change in activity: ems controllers run in the ready mode
2 indicates activity: ems controllers run in the ready mode
For example, the self-learning matrix below shows the following:
Day 1 to day 3: the ems controller runs in the ready mode from 06:00 to 18:00
Day 4 and day 5: the ems controller runs in the ready mode from 06:00 to 20:00
Day 6: the ems controller runs in the ready mode from 08:00 to 14:00
Day 7: the ems controller remains in the saving mode.
Note
The self-learning matrix starts the moment the ems controller is first switched on and is not
synchronized with calendar days. However, the diagram below starts at 00:00 on Day 1 for
clarity

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elstat ems25 Series and is the answer not in the manual?

Elstat ems25 Series Specifications

General IconGeneral
BrandElstat
Modelems25 Series
CategoryControl Systems
LanguageEnglish

Related product manuals