54 MES1000, MES2000 Ethernet Switches
destination-url:
(1..160) characters
destination address in SNMP format
- source_url—source location of the file being copied
- destination_url—destination location for the file to be copied
to
Copy the system firmware file from the server into non-volatile
memory.
Copy the load file from the server into non-volatile memory.
copy source_url
running-config
Copy configuration file from the server into the current
configuration.
copy source_url
startup-config
Copy configuration file from the server into the initial
configuration.
copy running-config
destination_url
Save the current configuration on the server.
copy startup-config
destination_url
Save the initial configuration on the server.
copy running-config
startup-config
Save the current configuration into the initial configuration.
Save the current configuration into the specified backup
configuration file.
Save the initial configuration into the specified backup
configuration file.
copy running-config
backup-config
Save the current configuration into the backup configuration
file.
copy startup-config
backup-config
Save the initial configuration into the backup configuration file.
Display the list of files in the flash memory
more {flash://<file> |
startup-config |
running-config |
mirror-config | <file>}
<file> - (1..160) characters
Show file contents.
- startup-config—show the contents of the initial configuration
file
- running-config—show the contents of the current
configuration file
- flash:// - show files from USB flash drives
- mirror-config—show the current configuration file contents
from the mirror
- file—filename
File contents are shown in ASCII standard, except for
image files that are shown in hexadecimal format.
*.prv files are not shown.
Delete the file from the device flash memory.
*.prv, image-1 and image-2 files cannot be removed.
Delete the initial configuration file.
boot system
[unit unit] {image-1|
image-2}
Define the system firmware file, that will be loaded on startup.
- unit—number of the device in a stack (for standalone switch,
this parameter is not used)
Show contents of the current configuration file.
Show contents of the initial configuration file.
Show the active system firmware file, that device loads on
startup.
- unit—number of the device in a stack (for standalone switch,
this parameter is not used).
During command execution, [unit unit] parameter is
available in the stackable mode only.
Save the current configuration into the initial configuration file.
Change the filename.
- url—current filename
- new_url—new filename