58 MES1000, MES2000 Ethernet Switches
5.9 System time configuration
Automatic daylight saving change is performed according to US and EU standards by
default. You can set any date and time for daylight saving change and the set back process
in the configuration.
Privileged EXEC mode commands
Command line request in Privileged EXEC mode appears as follows:
console#
Table 5.28 System time configuration commands in Privileged EXEC mode
Command
Value
Action
clock set hh:mm:ss day
month year
clock set hh:mm:ss month
day year
hh (0..23), mm(0..59),
ss (0..59), day (1..31);
month (Jan..Dec);
year (2000 2037)
Manual system time setting (this command is available to
privileged users only).
hhhours, mmminutes, ssseconds
dayday; monthmonth; yearyear.
show sntp configuration
-
Show SNTP protocol configuration.
show sntp status
-
Show SNTP protocol status.
EXEC mode commands
Command line request in EXEC mode appears as follows:
console>
Table 5.29System time configuration commands in EXEC mode
Command
Value
Action
show clock
-
Show system time and date.
show clock detail
Additionally show timezone and daylight saving settings.
Global configuration mode commands
Command line request in global configuration mode appears as follows:
console(config)#
Table 5.30 List of system time configuration commands in global configuration mode
Command
Value/Default value
Action
clock source sntp
-/external source is not
used
Use the external source for setting system time.
no clock source
Deny the utilization of the external source for setting system
time.
clock timezone zone
hours-offset
[minutes minutes-offset]
zone: (1..4) characters/
no zone description
hours-offset:
-12..+13/0;
minutes-offset:
(0..59)/0;
Set the timezone value.
- zoneabbreviation of the phrase (zone description)
- hours-offsethour offset from UTC zero meridian
- minutes-offsetminute offset from UTC zero meridian
no clock timezone
Restore the default value.