VoIP subscriber gateways  21 
–  Daylight saving (DST start) – setting of the moment and time of daylight saving by the format of 
‘week number, day, hour, minutes’, for example the last Sunday of July at half night; 
–  DST  end  –  you  can  set  date  and  time  of 
daylight  saving  time  (DST)  in  the  format 
‘week  number,  week  day,  month,  hours, 
minutes’, for example, the second Sunday 
of October, 00 hours 00 minutes; 
–  DST  offset  (minutes)  –  set  the  time  shift 
value, in minutes; 
–  Enable NTP – set the flag to enable synchronization of the device system time from specified NTP 
server. 
–  NTP Server – IP-address/domain of NTP-server.  
Access Ports: 
–  HTTP port – specify port for access via HTTP protocol; 
–  HTTPS port – specify port for access via HTTPS protocol; 
–  Telnet port – specify port for access via Telnet protocol;  
–  SSH port – specify port for access via SSH protocol; 
–  FTP port – specify port for access via FTP protocol.  
To save changes into non-volatile memory of the device, click ‘Save Changes’ button. To record settings 
into non-volatile memory, click ‘Apply’ button. 
3.1.1.2 ‘Access passwords’ submenu 
Use the submenu to assign passwords for administrator and unprivileged user.  
TAU-8.IP includes two types of the users: admin and user. Admin (by default, password is password) has 
the full access to the device (read and write any settings, full device status monitoring). User (default password 
is user) may access device status monitoring without reading and recording configuration data.  
Administrator  password  is  used  for  administrator  access  via  Web-interface,  Telnet  and  SSH  protocols. 
User password is used for unprivileged user access via Web, Telnet, SSH and FTP.