Maintenance
33
Remove the 4 screws (8) which hold the assembly (6/7) on the
furnace.
Lift the assembly (6/7) in straight vertical direction.
Unscrew the four screws and nuts which hold the parts (6) and (7)
together.
Replace the lance (11)
Replace the O-ring (10)
Replace the O-ring (9)
Do reassembling in reverse order
4.8 Heating elements replacing
DANGER
G0002
Mortal danger from electric shock
Exposed power contacts - High Voltage
- An electric shock can cause injuries in the form of burns and
cardiac arrhythmia, respiratory arrest or cardiac arrest.
Disconnect the mains power plug before opening the
analyzer’s cabinet.
Fig. 9: Operating procedure for replacement of heating elements
Remove the combustion tube. See chapter “Combustion tube
replacing”
Remove the two screws (1) fixing the right hand side panel (2) of the
analyzer’s cabinet.
Slightly tilt the panel to the right and carefully lift it. The loader should
not be shifted otherwise it will lose its mechanical adjustment.
Unscrew the two screws (3) and remove the heat shield (4).
Unscrew the four nuts (5) and remove the panel (6).
Loose the four nuts (7) and remove the two double clamps (8).
Remove the four ceramic spacers (9).
Apply the panel (6) in its original place and manually fix it with two
nuts (5) diagonally to prevent it from falling down.
Unscrew the four screws (10) and remove the panel (11).
Remove the two nuts (12)

Other manuals for ELTRA CS-580A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ELTRA CS-580A and is the answer not in the manual?

ELTRA CS-580A Specifications

General IconGeneral
BrandELTRA
ModelCS-580A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals