EM Test CWS500 N2
User manual V 3.00 33 / 38
Interfaces
Serial Interface USB
Parallel IEEE 488 GPIB interface Addresses 1 - 30 selectable
All interfaces are included as standard features.
Powermeter PM 1000
Frequency range 9kHz 1000 MHz
Input range Monitor -45 dBm ... +13 dBm
FWD power -50 dBm ... +13 dBm
REV power -50 dBm ... +13 dBm
Max. Input MONITOR 13dBm approx. 1.3 Vrms
Accuracy < 0.5 dB (0.1MHz...400MHz)
< 1.0 dB (0.009MHz...1000MHz)
Bi directional coupler
Frequency range 9 kHz .. 1000MHz
Power (maximum) 200Watt
Coupling factor 40 dB
Directivity 25 dB typical
Insertion loss approx. 1 dB (including relays)
VSWR 1.25 maximum
RF Amplifier 150W
Frequency range 9 kHz .. 400 MHz
Output power nominal 20kHz...300MHz 52dBm
Output power minimum 9kHz...400MHz 51dBm
Gain approx. > 51.7dB
Compression at nominal output power 1dB (typical)
Harmonic distortion > 20dBc at max. power
Input Maximum 0 dBm (1mW)
Input VSWR <2:1 typ.
General data CWS500N2.1
Dimensions ( HxWxD) 19"/12HE (600 x 550 x 800) mm
Weight approx. 84.0kg
Power supply 110-230V/ 50/60Hz
Input power max. 1430W
Power factor cos=0,98 at max output power acc. to IEC 555
Fuse 2x6,3AT (115V / 230V)
Cooling active cooling, air ventilation
Environment conditions 10°C - 40°C
Humidity Max. rel. humidity 80% up to 31C Decreasing linearly to 50% at 40C