Wiring Diagram for :
EMC
®
POWERJET
®
model: 5846E
dwg: PJ-5846E-5HP-440V-3PH-40A
BC-07-06-2005
AUTOMATIC PARTS WASHER
Electric Heated (440V)
with standard 5HP pump Motor (3)
440Volt / 3 (three phase) / 40Amps
Drawing Not to Scale
Control Box Side View
(cover removed)
30 min.
PUMP
TIMER
BULB
BULB
7 - DAY
TIMER
DOOR
SWITCH
THERMO
-STAT
1 LINK
440Volt
100VA
TRANSFORMER
HEATER CONTACTOR
HEATER CONTACTOR
PUMP CONTACTOR
Over Load Relay
TO
TURNTABLE
MOTOR
AC POWER IN
440V, 3, 40A
Ground to chassis
Copper Capillary Tubing
Control Box
Front View
Control Box
Rear View
Electric models:
5846E,
5HP,
440V-3ph-40A
To Pump Contactor (Power In)
Heater Box Cover
(cut-away view)
Drawing Not to Scale
440V, 4500W, (6) Heater
Elements
5HP,
3 Phase
MOTOR
Heavy Duty,
280GPM,
SEALLESS
PUMP
Drawing Not to Scale
PUMP
WELL
IMPORTANT !
CHECK THAT
PUMP MOTOR
ROTATION IS
CLOCKWISE AS
VIEWED FROM
TOP !
PUMP ROTATION
CLOCKWISE FROM TOP
Float
Switch
Thermostat Probe in sleeve
AC POWER IN,
440V, 3ph, 40A
Note:
Unit will operate at
400V to 480V,
3 phase, power
30
20
10
Turn
Past
0FF
MINUTES
OFF
220
120
160
200
180
140
100