94 “Extended time” procedure
Section 4: Orifice plate installation and removal instructions Owner and operator manual
January 2015 3-9008-001 Rev M
Step 47 Step 47A
PRESSURIZED FLUID HAZARD
Using the Grease Gun (23), inject the grease into the slide valve seat channels at a rate of 4 to 6
turns per minute and only under the following conditions:
Bleeder Valve is open.
Sealing Bar/Clamping bar is in place and tight.
Injection of the grease at a faster rate will lead to the separation of the valve strip from the valve
seat, resulting in release of pressurized fluid which may cause serious injury or death.