Owner and operator manual Section 2: Installation
3-9008-001 Rev M January 2015
Orifice Plate Installation 39
5. Orient the 2”-8” Plate Carrier (8DMC) assembly with the notch down. The notch end of
the 2”-8” Plate Carrier (8DMC) assembly must enter the Senior first.
Important
Install the Plate Carrier (8DM or 8DMC) assembly into the Senior with the gear rack facing
downstream and the notched end down (refer to Figure 2-3 and Figure 2-4). Failure to align and
install Plate Carrier (8DM or 8DMC) assembly as instructed will cause erroneous measurement
results.
6. Align the plate carrier gear rack teeth to the Plate Carrier (8DM or 8DMC) shaft pinion
on the Senior when installing the Plate Carrier (8DM or 8DMC) assembly.
Figure 2-3 Plate Carrier (8DM or 8DMC) plunger and notch location