Owner and operator manual Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M January 2015
“Quick change” procedure 59
Step 11 Step 11A
12. Return the stem to the Grease Gun (23) and begin turning it clockwise by hand into the
Grease Gun (23) until resistance is felt. Once this is done, use the supplied Operating
Wrench (2) to continue to turn the stem clockwise, at a rate of 4 to 6 turns per minute.
PRESSURIZED FLUID HAZARD
Using the Grease Gun (23), inject grease into the slide valve seat channels at a rate of 4 to 6 turns
per minute and only under the following conditions:
Bleeder Valve is open.
Sealing bar/Clamping bar is in place and tight.
Injection of the grease at a faster rate will lead to the separation of the valve strip from the valve
seat, resulting in release of pressurized fluid which may cause serious injury or death.