62 “Quick change” procedure
Section 4: Orifice plate installation and removal instructions Owner and operator manual
January 2015 3-9008-001 Rev M
Step 15
16. Slide the Clamping Bar (12 or 12HP) containing the Clamping Bar Screws (11), the
Sealing Bar (9 or 9HP) from the Top (14).
Step 16-17
17. Remove the Sealing Bar Gasket (9A, 9A-HP or 9CF) from the Top (14).
18. Rotate the Upper Plate Carrier Shaft (7), located in the Top (14) with the Operating
Wrench (2), until the Plate Carrier (8DM or 8DMC) extends outside of the Top (14) and