98 Appendix 1 Parameters
EV2000 Series Universal Variable Speed Drive User Manual
Group 7: Terminal Function Parameters
Para. Name LCD Display Setting Range Unit
Factory
setting
Modif
F7.00
Function of
multi-function
terminal X1
TERMINAL
X1 FUNC
0:No function
1:Preseting frequency 1
2:Preseting frequency 2
3:Preseting frequency 3
4:Setting Acc/Dec time 1
5:Setting Acc/Dec time 2
6:Normally open input terminal for external fault signal
7:Normally open input terminal for external fault signal
8:Terminal for external reset signal (RESET)
9:Terminal for inputting Jog running forward command
10:Terminal for inputting Jog running reverse command
11:Coast to stop (FRS)
12:Terminal for inputting command of increasing frequency (UP)
13:Terminal for inputting command of decreasing frequency (DN)
14: Terminal for inputting command of pausing PLC operation
15: Terminal for inputting command of disabling Acc/Dec
16: Terminal for 3-wire operation control
17: Normally open contacts for input external interruption
18: Normally closed contacts for input external interruption
19:DC injection braking at stop
20:close loop inactive
21:PLC inactive
22:reference frequency input channel 1
23:reference frequency input channel 2
24:reference frequency input channel 3
25:Frequency reference is input via terminal CCI forcibly
26:Reserved
27:Terminal control mode is forcibly enabled
28:Command input channel 1
29:Command input channel 2
30:Multi-voltage terminal 1
31:Multi-voltage terminal 2
32:Multi-voltage terminal 3
33:Start of traverse operation
34:Clear the traverse operation status
35:external stopping command(valid for all control mode)
36:Reserved
37:Drive operation disabled
38:Reserved
39:Clear the length
40:Clear the auxiliary reference frequency
41:Clear the memorized information at the stop process of PLC
operation
42:Counter clearing signal input
43:Counter trigger signal input
44:Length data input
45:Pulse frequency input
46:Single phase speed measuring input
47:speed measuring input SM1(only for X7)
48:speed measuring input SM2(only for X8)
1 0
×
F7.01
Function of
multi-function
terminal X2
TERMINAL
X2 FUNC
F7.02
Function of
multi-function
terminal X3
TERMINAL
X3 FUNC
F7.03
Function of
multi-function
terminal X4
TERMINAL
X4 FUNC
F7.04
Function of
multi-function
terminal X5
TERMINAL
X5 FUNC
F7.05
Function of
multi-function
terminal X6
TERMINAL
X5 FUNC
F7.06
Function of
multi-function
terminal X7
TERMINAL
X7 FUNC
F7.07
Function of
multi-function
terminal X8
TERMINAL
X7 FUNC
F7.08
FWD/REV
running mode
setup
OPR CTR
MODE
0: 2-wire operation mode 1
1: 2-wire operation mode 2
2:3-wire control mode 1-self holding function(any terminal of terminals
X1~X8)
3:3-wire control mode 2-self holding function(any terminal of terminals
X1~X8)
1 0
×
F7.09 UP/DN speed UP/DN SPEED 0.01~99.99Hz/s 0.01Hz/s 1.00Hz/s